OncoSwift® Ovarian Comprehensive

Unique Identifier:

ML-L012


Name on Requisition:

OncoSwift® Ovarian Comprehensive


Product Line:

LB


Panel Group:

Liquid Biopsy Panels


Panel Name:

OncoSwift® Ovarian Multi-Omics


Methodology

Molecular
NGS


Test Description and clinical significance

Genes
AKT1, ARAF, ATM, ARID1A, BARD1, BRAF, BRCA1, BRCA2, BRIP1, CCNE1, CDK12, CHEK1, CHEK2, CTNNB1, ERBB2, ESR1, FGFR1, FGFR2, FGFR3, FANCA, FANCL, KIT, MAP2K1, MET, MLH1, MSH2, MSH6, MTOR, NTRK1, NTRK2, NTRK3, NF1, NRG1, PALB2, PIK3CA, PMS2, PPP2R1A, PTEN, RAD51C, RAD51D, RAD54L, RET, TP53.

Disease:
ovarian cancers

The OncoSwift® Ovarian Comprehensive Panel analyzes the genomic landscape of epithelial ovarian cancers. It detects mutations, fusions, and copy number variations, including BRCA1/2 and homologous recombination repair genes, providing diagnostic, prognostic, and therapeutic guidance, especially for PARP inhibitor eligibility.


Specimen Requirements

Preparation:
PB

Collection:
Two tubes of peripheral blood (10mL/tube) are collected in PAXgene Blood ccfDNA tube

Stability:
7 to 10 days at room temperature

Unacceptable Conditions:
Specimen submitted is not in the PAXgene Blood ccfDNA Tubes or n the PAXgene Blood ccfDNA tube after expired date. Insufficient specimen (less than 10 mL whole blood/tube). Specimen is leaking from the collection tube, or the glass tube is broken. Gross hemolysis. Bacterial overgrowth Submitted with incomplete requisition form (unless a requisition is subsequently sent). Unlabeled or improperly labeled specimens, without contact information or when failing to reach the ordering physician for clarification. cfDNA shipped in inappropriate temperature .


Storage & Transport

7 to 10 days at room temperature


CPT(s)

81464


New York Approved

Yes


TAT

7


Requisition Type

LB


Levels of Service

Full


DexS Code

Z0CH


Prefix

MI


*The CPT codes provided are for informational purposes only and are based on AMA guidelines The billing party is solely responsible for correct CPT coding.

Discover more.

A Model Experience

With core values rooted in service and integrity, our leadership team sets the bar high.

We consistently strive to set the model for exactly how a reference laboratory should engage with both physicians and patients.

Accredited and Certified

siParadigm is accredited by CLIA (Clinical Laboratory Improvement Amendments) and certified by CAP (College of American Pathologists).

We also hold select state licensure where required.